MIL-DTL-62481A(AT)
150
140
130
126
120
110
106
100
10
100K
10
100
1K
10K
Frequency (Hz)
FIGURE 5. Conducted susceptibility.
TABLE I. Radiated susceptibility limits.
Frequency range
limit level (volts/meter)
10 kHz 1/ to 2 MHz 2/
20
2 MHz to 30 MHz
50
30 MHz to 1 GHz 3/
50
1 GHz to 18 GHz
50
18 GHz to 40 GHz
50
1/ kHz = kilohertz 2/ MHz = megahertz 3/ GHz = gigahertz
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.1.1).
1. Preproduction inspection (see 4.1.1.1).
2. Initial production inspection (see 4.1.1.2).
b. Conformance inspections.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.